Making Sense of Filter Classifications for Fume Extractors
W3, HEPA, M-Class, H13, H14, F9, efficiency, high efficiency: These are some of many terms used to describe and classify fume extractors and filters. So what do they all mean? How do they compare? And are they all relevant to welding fume extractors?
A Quick Summary of Fume Extractor and Filter Classifications
This table provides a condensed and abbreviated summary of common filter/extractor classification terms.
This is to demonstrate that these terms are all describing different measurements and test conditions, for different components and intended applications. None of these terms are like-for-like... and this is why comparing % percentage efficiency ratings alone is neither reliable nor meaningful, unless comparing within the SAME class or standard.
|
Term |
Related Standard / Scope | Applies To | Efficiency Requirement & Test Medium / Aerosol |
| W3 |
AS/NZS ISO 21904 |
Entire extractor machine, welding fume specific | ≥99 % using real welding fume, mostly <1µm |
| M-Class |
IEC 60335-2-69
|
Filter | >99.9 % using quartz dust, 0.2-2µm |
| Entire extractor machine | >99.9 % using limestone dust, mostly <5µm | ||
| HEPA or H13/14 | EN 1822 / ISO 29463. High-efficiency air filters | Filter only | H13 ≥99.95 %, H14 ≥99.995 % using oil & other aerosols, ~0.1-0.25 µm |
| F9 | EN 779 General ventilation filters (now replaced by ISO 16890) |
Filter only | ≥95 % avg using oil aerosol at 0.4 µm |
| ePM.. | AS / ISO 16890 General ventilation filters |
Filter only | Varies depending on class. Using oil or salt aerosols. |
What is Filtration "Efficiency" ?
Efficiency is the percentage of particles a filter or extraction machine stops, compared with what goes into it. For example, a 99% efficient unit lets 1% through.
This measurement only means something when you know how it was tested, including:
Filter vs complete/assembled machine: A filter (or filter medium material) tested on its own in a lab will nearly always score higher than when it is tested in a complete machine, where air can leak past seals, gaskets and the cabinet.
Particle size: This makes a big difference. For example, an M-class >99.9% rating measured on relatively coarse limestone dust (up to 5µm) can't be compared directly with W3 >99.0% rating that is measued with welding fume (typically much finer particles of less than 1µm). Testing with finer particles is more rigorous and requires better filtration.
What is the Best Classification for Welding Fume Extractors and Filters?
As we can see in the table above, AS/NZS ISO 21904 "W3" is the only true "welding-fume-specific" filtration measurement/standard.
So why do some welding fume extractors use other classifications? There's a few reasons for this, including:
- Fume extractor models are often developed to suit multiple industries and applications, with the same base unit rated to classifications (such as M-class) that are recognised across various industries.
- AS/NZS ISO 21904 "W3" does not apply ALL types of welding fume extractors. Down-draft tables, for example, are outside the scope of this standard. This means that other classifications are used to provide an indiciation of filtration performance.
Summary: Where AS/NZS ISO 21904 "W3" classification is provided / applicable, obviously this is the the most relevant classification for welding fume applications. And while classifications like M-Class are not welding-fume-specific, they do still provide some indication of fume filtration and/or extraction performance, provided they are understood in context.
So What is W3 Rating?
The W3 rating relates to one aspect of AS/NZS ISO 21904: the fume extractor’s overall separation efficiency, rather than the efficiency of the filter element alone. In simple terms, it measures how effectively the complete unit removes (separates) welding fume from the air AFTER the fume has been captured.
To achieve W3 classification, the unit must demonstrate a separation efficiency of at least 99% when tested in accordance with the standard.
This should not be confused with capture efficiency, which relates to the overall volume of fume removed from the workplace. More on this below.
But Wait There's More: Separation vs Capture Efficiency
If You Don’t Capture Fume, You Can’t Filter It.
A filtration efficiency % tells you nothing about capture, meaning how well the extractor draws fume away from the workplace. A unit with a very high filter efficiency % does little good if the fume is not effectively captured in the first place.
This fundamental point is often overlooked. The first and most important step in controlling welding fume and meeting the legal workplace exposure limit (WEL) is capturing the fume at its source.
If sufficient fume volume is not captured, you will not achieve compliance with WEL.
Currently there are no official standards or classifications for overall capture efficiency (in terms of total volume), which makes it challenging to determine the performance of one fume extractor vs another in this respect.
At Weldclass, extraction volume performance has always been a top priority in the design of our ALLCLEAR range. ALLCLEAR fume extractors deliver high airflow rates and efficient internal design to maximise fume capture and support workplace compliance. Read more about this here.
Get a Quote | Request a Demo View The ALLCLEAR Extractor Range
While all care has been taken to ensure the information presented is accurate, Weldclass accepts no responsibility for any errors or omissions in this article. The information given is of a general nature only, intended to give readers a basic overview of the topics presented, and does not take into account the specific circumstances of any individual workplace or application. It may be simplified or abbreviated, is not a complete or exhaustive summary of AS/NZS ISO 21904 or any other standard or regulation, and should not be used as a substitute for professional advice (such as from a qualified occupational hygienist, WHS professional or legal adviser). Readers should refer to the full text of the applicable standards for complete and authoritative requirements. Work health and safety laws and exposure limits may vary between states and territories and are subject to change, and the information in this article is current only as at the date of publication. All applicable standards (including Australian standards), codes of practice, industry guidelines and regulations should be consulted and followed. Weldclass does not condone or recommend using any equipment in a manner that is contrary to WHS regulations, Australian standards requirements or manufacturer’s instructions. E.&O.E.